5 Technical data
Service manual
63
ATXP20~35L2V1B + FTXP20~71L2V1B + ARXP20~35L2V1B +
RXP20~71L2V1B
Split Comfora R32
ESIE18-01 – 2019.02
5.7 Field settings
5.7.1 Field settings: Indoor unit
To control the indoor unit fan during thermostat
off
1 Press , , and simultaneously.
2 Press .
3 Select SU.
4 Press to confirm.
5 Press .
6 Select 4.
7 Press to confirm.
8 Press .
9 Select 0 (0: fan ON, 1: fan OFF).