2 | Components
Service manual
44
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
cd a b a
a 4‑way valve pipe
b 4‑way valve
c Putty
d Insulation
5 Install the putty (if available) and the insulation (if available) in their original
location.
6 Install the 4‑way valve coil on the 4‑way valve body, see "2.1.2 Repair
procedures"[442].
7 Add refrigerant to the refrigerant circuit, see "3.2.2 Repair
procedures"[4137].
To install the 4-way valve coil
1 Install the 4‑way valve coil on the 4‑way valve body.
c a b
a Screw
b 4‑way valve coil
c 4‑way valve body
2 Install and tighten the screw to fix the 4‑way valve coil.
3 Route the 4‑way valve coil harness towards the appropriate PCB.
4 Connect the 4‑way valve coil connector to the PCB.
WARNING
When reconnecting a connector to the PCB, do NOT apply force, as this may damage
the connector or connector pins of the PCB.
5 Fix the 4‑way valve coil harness using new tie straps.
Is the problem solved? Action