2 | Components
Service manual
46
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
a
a
a Damper
INFORMATION
The compressor dampers may look different.
Compressor dampers and piping are in
a good condition?
Action
Yes Perform an electrical check of the
compressor, see "2.2.1Checking
procedures"[445].
No Replace the compressor, see
"2.2.2Repair procedures"[450].
To perform an electrical check of the compressor
1 First perform a mechanical check of the compressor, see "2.2.1 Checking
procedures"[445].
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10VDC before proceeding.
2 Remove the cover of the compressor wire terminals.