2 | Components
Service manual
59
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
CAUTION
Overheating the valve will damage or destroy it.
4 After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
a b c
a Putty
b Expansion valve pipe
c Expansion valve body
a b
a Expansion valve pipe
b Expansion valve body
INFORMATION
The expansion valve and motor can have a different configuration / layout.
5 Reinstall the putty.
6 To install the expansion valve motor, see "2.3.2Repair procedures"[456].
7 Add refrigerant to the refrigerant circuit, see "3.2.2 Repair
procedures"[4137].
About the installation of the expansion valve motor
NOTICE
Select the correct type.
To install the expansion valve motor with clip
1 Install the expansion valve motor on the expansion valve body.