Loading...
2 | Components
Service manual
83
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
Class 20~35
a
a HAP LED
Class 42~50
a
a HAP LED
Does the HAP LED blink in regular
intervals (1second ON/1second OFF)?
Action
Yes Return to "2.11.1Checking
procedures"[481] of the main PCB and
continue with the next procedure.
No Replace the main PCB, see
"2.11.2Repair procedures"[485].
To check if the correct spare part is installed
Prerequisite: First perform all earlier main PCB checks, see "2.11.1 Checking
procedures"[481].
1 Visit your local spare parts webbank.
2 Enter the model name of your unit and check if the installed spare part
number corresponds with the spare part number indicated in the webbank.
NOTICE
Also check that the correct spare part is installed for the capacity adapter.