SK2014SON002TechMnlFMCD003
C.1.9. Louver
ForremotehandsetwithControlBoxI(IntegratedFullControlVersion)
Whenevertheindoorfanisrunning,thelouvercanswingorstopatthedesiredposition.
Louverangle:0~100º,opensclockwisewithwidestangleat100º.
Swingangle:35~100º,opensclockwiseto68º.Belowarethe4fixed
positionswhichcanbesetfromwireless
LCDhandset.
Position Angle
1 35º
2 57º
3 83º
4 100º
ForwiredwallpadwithControlBoxI(IntegratedFullControlVersion)
Louverangle:0~100º,opensclockwisewithangleat100º.
Swingangle:35~100º,opensclockwiseto68º.Usermaystoplouveratanydesiredpositionbetween35~100º.
C.1.10. Buzzer
Ifacommandisreceivedbytheairconditioner,themasterunitwillrespondwith2beepsforeachsetting,
whiletheslaveunitwillrespondwith1beep.
C.1.11. AutoRestart
Thesystemusesnonvolatilememorytosavethepresentoperationparameterswhensystemisturnedoffor
incaseofsystemfailureorcessationofpowersupply.OperationparameterswhenusingahandsetareMode,
SetTemperature,Swing,andFanSpeed.Whenusingawallpadtheparametersare
Mode,SetTemperature,
Swing,andFanSpeed,aswellasthe7dayON/OFFTimerprogram.Whenpowersupplyresumesorthesystem
isswitchedonagain,thesameoperationsaspreviouslysetwillfunction.