Page 46 of 62
SK2014‐SON‐002‐TechMnl‐FMCD‐003
C.4.3. OnboardConfiguration
Thereis1DIPswitchsetonthePCB:
DIPB(4positions)
SW1:configuredfordifferentmodulatingsignal.
SW2–SW4:brushlessDCfanmotorconfiguration.
Code State Description
SW1
0 PCBconfiguredfor0~5VDCmodulatingsignalinput.
1 PCBconfiguredfor0~10VDCmodulatingsignalinput.
MODEL SW2 SW3 SW4 Hi Med Low
FMCD‐04
0 0 0 700 600 500
FMCD‐06
0 0 1 930 700 600
FMCD‐12
0 1 0 930 700 600
FMCD‐15
0 1 1 1150 800 700
FMCD‐18
1 0 0 1300 1100 900
FMCD‐20
1 0 1 1100 900 800
FMCD‐24
1 1 0 1350 1200 900
DefaultRPM 1 1 1 Setbycustomerrequirement
C.4.4. ControlLogicSpecification
1. PowerOnSetting
Whenanyfanspeedisselected,theunitisturnedon.Whenalloftherelaysareoff,theunitisturnedoff.
2. Swing/Louver
Whentheunitisturnedon,thelouverwillopentothelargestangleat100º,thenmoveto
theoperatingangle
at87º.Whentheunitisturnedoff,thelouverwillclose.
3. SignalInput
WhenAutospeedisturnedON,theunitisturnedonandthemotorrunsat200RPM.ECmotorRPMwillbe
changedbythesignalvoltage.