9. After adjustment, torque the locknut (L024) to 12 N•m [9 lbf•ft].
Caution
Do not over torque.
10. Shut down the prime mover.
11. Remove gauges and replace plugs.
Service Manual
H1T 045/053, 060/068 Axial Piston Tandem Pumps
Adjustments
©
Danfoss | September 2020 AX152886481761en-000405 | 45