The Basic Closed Circuit
Hydraulic lines connect the main ports of the pump to the main ports of the motor. Fluid flows in either
direction from the pump to the motor and back. Either of the hydraulic lines can be under high pressure.
In pumping mode the position of the pump swashplate determines which line is high pressure as well as
the direction of fluid flow.
Case Drain and Heat Exchanger
The pump and motor require case drain lines to remove hot fluid from the system. The pump and motor
drain from the topmost port to ensure the cases remain full of fluid.
The motor case drain can connect to the lower drain port on the pump housing or it can tee into the case
drain line upstream of the heat exchanger. A heat exchanger with bypass valve cools the case drain fluid
before it returns to the reservoir.
Service Manual
H1T 045/053, 060/068 Axial Piston Tandem Pumps
Introduction
8 |
©
Danfoss | September 2020 AX152886481761en-000405