Charge check / HPRV adjustment
The charge check/HPRV combines the charge check and high pressure relief functions. Whenever you
replace a charge check/HPRV, operate the vehicle/machine through its full range of functions to ensure
proper pump operation. The charge check/HPRVs are preset at the factory, no adjustment is possible.
Checking for proper charge check / HPRV operation
If you suspect charge check/HPRV malfunction, swap valves and test operation. If the symptoms switch
direction, replace the faulty valve.
Service Manual
H1T 045/053, 060/068 Axial Piston Tandem Pumps
Adjustments
46 |
©
Danfoss | September 2020 AX152886481761en-000405