7. Pull assembly fixture out before installing control screws.
Solenoid shaft
Feedback pin
Adjusting
screw
(cam)
Maximum
adjustment
less than 120°
Control spool
Remove plug (D065) and verify the swashplate feedback pin is properly positioned between control
feedback arms.
8. Install the control module and six cap screws (D250).
9. Using a 5 mm internal hex wrench, fasten control to pump with screws (D250).
10. Torque screws to 13.3 N•m [9.8 lbf•ft] following torque sequence shown.
1
2
3
6
5
4
Torque sequence
(6 screw control)
D065
For proper neutral adjustment procedure, refer to Control Neutral Adjustment on page 50 topic.
W
Warning
Calibration of sensor output in vehicle software is mandatory after sensor replacement because output
signal can vary from one sensor to the other.
Service Manual
H1T 045/053, 060/068 Axial Piston Tandem Pumps
Minor repair
©
Danfoss | September 2020 AX152886481761en-000405 | 63