TP7001
18
GB
2.0 Advanced Functions
2.1 Mode
The MODE button allows the operation of the programmed events 
to be altered between:
1.  Auto mode
 a.  6 events
 b.  4 events
 c.  2 events
2.  Allday mode
  a.  Only the  rst and last programmed events run
3.  Thermostat mode
a.  Thermostat mode means that all time pro les are ignored 
and the temperature is controlled at whatever temperature is 
manually set by the user.
Note: If set for two events per day, then Auto and Allday are e ectively 
the same and so the MODE button will only change between Auto 
and Thermostat (O  ) modes.
When in Auto or Allday modes, the clock symbol is displayed to 
indicate the programmed events will be followed.
The TP7001 can be converted to control at a constant user selected 
temperature, instead of following the set programme.
Press and hold the  and  buttons together until the 
display changes to the colon  ashing and default frost 
temperature (5°C).
Press the  or  buttons to alter temperature as 
required.
NOTE: The unit will remain in thermostat mode until  
and  are pressed and held together again.
2.2 Thermostat mode