5
VLT type 3502 3504 3508 3511 3516 3522 3532 3542 3552 3562
Output current I
VLT,N
[A] 5.4 10.6 25.0 32.0 46.0 61.0 88.0 104.0 130.0 154.0
I
VLT, MAX
(60 s) [A] 5.9 11.7 27.3 35.2 50.6 67.3 96.8 114.4 143.0 169.0
Output S
VLT, N
[kVA] 1.9 4.0 10.0 12.7 18.3 24.3 35.1 41.4 51.8 61.3
Typical shaft output P
VLT, N
[HP] 1 3 5 10 15 20 30 40 50 60
Max. cable cross-section [AWG] 12 12 666442/02/02/0
Max. motor cable length [feet] 1000 (unshielded)*
Output voltage V
M
[%] 1-100, of AC line voltage
Output frequency f
M
[Hz] 0-120
Rated motor voltage V
M, N
[V] 200/220/230
Rated motor frequency f
M, N
[Hz] 50/60/87/100
Thermal protection during operation Integrated thermal motor protection (electronic); thermistor to DIN44081
Switching on output Unlimited (frequent switching may cause cut-out)
Ramp times [s] 0.1-3600
VLT type 3502 3504 3508 3511 3516 3522 3532 3542 3552 3562
Max. input current I
L, N
[A] 5.4 10.6 23.1 29.6 42.0 56.8 72.3 102.0 128.0 152.0
Max. cable cross-section [AWG] 12 12 666442/02/02/0
Max. pre-fuses [A] 25 25 40 50 60 80 125
1)
150
2)
150
2)
150
2)
Supply voltage [V] 3 phase 200/220/230 ±10%
Supply frequency [Hz] 50/60
Power factor / cos 0.9/1.0
Efficiency 0.96 at 100% load
Switching on input times/min. 2
Radio noise, cable borne VLT type 3502-04: EN 55011, class A, gr. 1, with option class B. gr 1
(with shielded cables) VLT type 3508-32 with option: EN 55011, cl. A, 1 VDE 0875, part 3, curve N
VLT type 3502 3504 3508 3511 3516 3522 3532 3542 3552 3562
Weight (lbs) Chassis (IP00) 16 16 ––––––––
and NEMA 1 (IP 20) – – 53 57 70 108 112 315 319 323
enclosure type NEMA 1 (IP 21) 18 18 ––––––––
NEMA 12 (IP 54) 24 24 75 81 106 139 143 315 319 323
Power loss Front –––––––357394409
at max. load [W] Heat sink –––––––588712884
Total 60 130 425 580 651 929 1350 945 1106 1293
Vibration test [g] 0.7
Relative humidity [%] VDE 0160 5.2.1.2.
Ambient temperature [°C] –10 ➔ +40. operation at full load
1)
–30/25 ➔ +65/70, storage/transport
Adjustable frequency drive protection Protection against grounding and short-circuiting
EMC standards Emission EN 50011, VDE 0875 part 3
Immunity EN 50082-2, IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5, VDE 0160, SEN 361503
* If shielded cable is to be used, consult Danfoss for cable length.
1) In the range –10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will
not fulfill the specifications.
2) Bussmann rapid type JJS integrated.
VLT
®
Series 3500
3 Phase, 200/220/230 Volt, Units