FC 302
P
m
R
min
R
br. nom
Flatpack IP65 for horizontal conveyors
R
rec
per item
Duty Cycle Ordering no.
T5 [kW]
[Ω] [Ω] [Ω/W]
% 175Uxxxx
PK37 0.37 620 1389 830/100 30 1000
PK55 0.55 620 929 830/100 20 1000
PK75 0.75 558 678 620/100 or 620/200 14 or 27 1001 or 0982
P1K1 1.1 382 453 430/100 or 430/200 10 or 20 1002 or 0983
P1K5 1.5 260.0 325.9 310/200 14 0984
P2K2 2.2 189.0 218.6 210/200 10 0987
P3K0 3 135.0 158.5 150/200 or 300/200 7 or 14 0989 or 2 x 0985
P4K0 4 99 117 240/200 10 2 x 0986
P5K5 5.5 72 84 160/200 8 2 x 0988
P7K5 7.5 50 61 130/200 6 2 x 0990
P11K 11 36.0 41.2 80/240 5 2 x 0090
P15K 15 27.0 30.0 72/240 4 2 x 0091
Table 5.15 FC 302 Mains: 380-500 V (T5)
IP65: flat pack type with fixed cable.
P
m
: Frequency converter nominal output power as HO.
R
min
: Minimum permissible brake resistor value by frequency converter.
R
br,nom
is the nominal resistor value that ensure a brake power on motor shaft of 150%/160% for 1 minute.
R
rec
: resistor value and resistance of the brake resistor.
Duty cycle: resulting duty cycle based on resistor power and frequency converter data.
How to Order
VLT
®
AutomationDrive FC 300 Design Guide, 0.25-75 kW
MG33BE02 - VLT
®
is a registered Danfoss trademark 101
5 5
http://www.RSPSupply.com/p-21462-Danfoss-131B8966-VLT-Automation-VT-Drive-VFD-FC301-230V-5-HP.aspx