NOTE
The LEDs are only visible when removing the LCP. Reaction
in case of an encoder error can be selected in
17-61 Feedback Signal Monitoring: None, Warning or Trip.
When the encoder option kit is ordered separately the kit
includes:
•
Encoder Option MCB 102
•
Enlarged LCP fixture and enlarged terminal cover
The encoder option does not support FC 302 frequency
converters manufactured before week 50/2004.
Min. software version: 2.03 (15-43 Software Version)
Connector
Designatio
n
X31
Incremental
Encoder (refer
to
Illustration 9.12)
SinCos Encoder
Hiperface® (refer
to Illustration 9.13)
EnDat Encoder SSI Encoder Description
1 NC 24 V* 24 V Output (21-25 V, I
max
:125 mA)
2 NC 8 VCC 8V Output (7-12V, I
max
: 200mA)
3 5 VCC 5 VCC 5 V* 5 V Output (5 V ± 5%, I
max
: 200 mA)
4 GND GND GND GND
5 A input +COS +COS A input
6 A inv input REFCOS REFCOS A inv input
7 B input +SIN +SIN B input
8 B inv input REFSIN REFSIN B inv input
9 Z input +Data RS-485 Clock out Clock out Z input OR +Data RS-485
10 Z inv input -Data RS-485 Clock out inv. Clock out inv. Z input OR -Data RS-485
11 NC NC Data in Data in Future use
12 NC NC Data in inv. Data in inv. Future use
Max. 5 V on X31.5-12
Table 9.9
* Supply for encoder: see data on encoder
Illustration 9.12 Incremental Encoder
NOTE
Max. cable length 150 m.
Options and Accessories
VLT
®
AutomationDrive FC 300 Design Guide, 0.25-75 kW
164 MG33BE02 - VLT
®
is a registered Danfoss trademark
99
http://www.RSPSupply.com/p-21462-Danfoss-131B8966-VLT-Automation-VT-Drive-VFD-FC301-230V-5-HP.aspx