0-10 Active set-up [1] Set-up 1 1 set-up TRUE - Uint8
0-11 Edit set-up [1] Set-up 1 All set-ups TRUE - Uint8
0-12 This set-up linked to [0] Not linked All set-ups FALSE - Uint8
0-13 Readout: Linked set-ups 0 N/A All set-ups FALSE 0 Uint16
0-14 Readout: Edit set-ups/channel 0 N/A All set-ups TRUE 0 Int32
0-2* LCP Display
0-20 Display line 1.1 small 30112 All set-ups TRUE - Uint16
0-21 Display line 1.2 small 30110 All set-ups TRUE - Uint16
0-22 Display line 1.3 small 30120 All set-ups TRUE - Uint16
0-23 Display line 2 large 30100 All set-ups TRUE - Uint16
0-24 Display line 3 large 30121 All set-ups TRUE - Uint16
0-25 My personal menu ExpressionLimit 1 set-up TRUE 0 Uint16
0-4* LCP Keypad
0-40 [Hand on] key on LCP [1] Enabled All set-ups TRUE - Uint8
0-41 [Off] key on LCP [1] Enabled All set-ups TRUE - Uint8
0-42 [Auto on] key on LCP [1] Enabled All set-ups TRUE - Uint8
0-43 [Reset] key on LCP [1] Enabled All set-ups TRUE - Uint8
0-5* Copy/Save
0-50 LCP copy [0] No copy All set-ups FALSE - Uint8
0-51 Set-up copy [0] No copy All set-ups FALSE - Uint8
0-6* Password
0-60 Main menu password 100 N/A 1 set-up TRUE 0 Int16
0-61
Access to main menu w/o
password [0] Full access 1 set-up TRUE - Uint8
0-65 Quick menu password 200 N/A 1 set-up TRUE 0 Int16
0-66
Access to quick menu w/o
password [0] Full access 1 set-up TRUE - Uint8
6.4.2 Digital In/Out 5-**
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion index
Type
5-0* Digital I/O mode
5-00 Digital I/O mode [0] PNP All set-ups FALSE - Uint8
5-01 Terminal 27 mode [0] Input All set-ups TRUE - Uint8
5-02 Terminal 29 mode [0] Input All set-ups x TRUE - Uint8
5-1* Digital Inputs
5-10 Terminal 18 digital input [8] Start All set-ups TRUE - Uint8
5-11 Terminal 19 digital input [0] No operation All set-ups TRUE - Uint8
5-12 Terminal 27 digital input [0] No operation All set-ups TRUE - Uint8
5-13 Terminal 29 digital input [0] No operation All set-ups TRUE - Uint8
5-19 Terminal 37 safe stop [1] Safe Stop Alarm 1 set-up TRUE - Uint8
5-3* Digital Outputs
5-30 Terminal 27 digital output [0] No operation All set-ups TRUE - Uint8
5-31 Terminal 29 digital output [0] No operation All set-ups x TRUE - Uint8
5-4* Relays
5-40 Function relay [0] No operation All set-ups TRUE - Uint8
5-41 On delay, relay 0.30 s All set-ups TRUE -2 Uint16
5-42 Off delay, relay 0.30 s All set-ups TRUE -2 Uint16
Programming Operating Instructions