2.1.2 Type Code
Illustration 2.2
Description Pos. Possible choice
Product group 1-3 Frequency converters
Series and product type 4-6 Micro Drive
Power size 7-10 0.18-7.5 kW
Mains voltage 11-12 S2: Single phase 200-240 V AC
T
2: Three phase 200-240 V AC
T 4: Three phase 380-480 V AC
Enclosure 13-15 IP20/Chassis
RFI filter 16-17 HX: No RFI filter
H1:
RFI filter class A1/B
H3:RFI filter A1/B (reduced cable length*)
Brake 18 B: Brake chopper included (from 1.5 kW and up)
X:
No brake chopper included
Display 19 X: No Local Control Panel
N:
Numerical Local Control Panel (LCP)
P: Numerical Local Control Panel (LCP)) with potentiometer
Coating PCB 20 C: Coated PCB
X.
No coated PCB
Mains option 21 X: No mains option
Adaptation A 22 X: No adaptation
Adaptation B 23 X: No adaptation
Software release 24-27 SXXX: Latest release - std. software
Table 2.1 Type Code Description
*See VLT
®
Micro Drive Design Guide, MG02K
Introduction
VLT
®
Micro Drive FC 51 Programming Guide
6 MG02C602 - VLT
®
is a registered Danfoss trademark
22
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-12769-Danfoss-132F0026-VFD-Micro-Drive-440V-5HP.aspx

Other manuals for Danfoss VLT Micro Drive FC 51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Micro Drive FC 51 and is the answer not in the manual?

Danfoss VLT Micro Drive FC 51 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Micro Drive FC 51
CategoryDC Drives
LanguageEnglish

Related product manuals