TECHNICAL FEATURES
5
5 TECHNICAL FEATURES
LYNX™ D432 / D432E Common Features
Electrical Features
Operating Voltage 10 to 30 V
Power Consumption
@ 12V
(Stand-by) 110 mA
@ 12V
(Typical) 245 mA
@ 10V
(Peak current) 305 mA
Communications Features
Standard Interfaces RS232, Keyboard emulation AT IBM, , USB COM emulation, USB
Keyboard emulation
Proprietary Interfaces USB Bulk, USB Generic HID
Environmental Features
Operating Temperature 0° to+ 55 °C (+32° to +131 °F)
Storage Temperature -20° to +70 °C (-4° to +158 °F)
Humidity 0 to 95% NC
Shock resistance IEC 68-2-32 Test ED – 1,8 m.
Mechanical Features
Dimensions 203 x 117 x 69 mm (8 x 4.6 x 2.7 inches)
Weight 265 g (9.3 oz.) without cable
Decoding Capability
1D Interleaved 2 of 5, Code39, Code32, Code128, EAN 128,
Code93, UPC/EAN/JAN, Codabar
2D PDF417, DataMatrix (ECC200)
Postal Codes POSTNET, PLANET, Japan Post, Australia Post, KIX Code,
Royal Mail Code (RM4SCC)
Imaging Option
Image 640 x 480 pixel format (VGA)
320 x 240 pixel format (CIF);
Graphic Format JPEG, 256 gray levels
BMP, 2, 16, 256 gray levels
TIFF, 2, 16, 256 gray levels
113