EasyManuals Logo

Datalogic Lynx Instruction Manual

Datalogic Lynx
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
LYNX™
1
1.5.1 Concatenation
It is possible to concatenate up to 4 different codes, set their length and enable the
intercode delay between them (the intercode delay is set in the specific interface
parameters, see pars. 2.4, 2.5, and 2.6). When enabling the delay (see par. 2.7.3)
one or more global headers and terminators are added to the decoded data. The
concatenation procedure may occur in different ways depending on the number of
codes to be decoded per image:
One Code Per Scan
If the code resulting from the single decoding of an image belongs to one of the
code families to be concatenated, it is saved to the Lynx™ memory waiting for
other codes to complete the concatenation.
If the code belongs to the same family of a code previously saved, it overwrites
the old one.
If the code resulting from the decoding does not belong to one of the code
families to be concatenated, it causes the concatenation failure and clears the
temporary memory. If the "Concatenation Failure Transmission" command is set
to "Tx codes causing failure" (see par. 2.7.3), this code will be sent in the output
message.
All Codes Per Scan
All codes resulting from the decoding of an image and belonging to one of the
families to be concatenated are saved to the Lynx™ memory waiting for other
codes to complete the concatenation.
If one or more codes resulting from the decoding belong to the same family of
codes previously saved, they overwrite the old ones.
When the image contains no code to be concatenated, the concatenation fails
and the reader temporary memory is cleared. If the "Concatenation Failure
Transmission" command is set to "Tx codes causing failure" (see par. 2.7.3), the
codes causing the concatenation failure will be sent in the output message.
12
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Datalogic Lynx

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Lynx and is the answer not in the manual?

Datalogic Lynx Specifications

General IconGeneral
Display diagonal2.7 \
Display resolution320 x 240 pixels
Display number of colors262144 colors
Flash memory0.512 GB
Internal memory0.256 GB
Internal memory typeRAM
Compatible memory cardsmicroSD (TransFlash), microSDHC
Processor familyPXA 310
Processor frequency0.806 GHz
Data networkHSPA+
Wi-Fi standards802.11b, 802.11g, Wi-Fi 4 (802.11n)
Bluetooth version2.0+EDR
Operating frequency800, 850, 900, 1900, 2100 MHz
Security algorithmsCCX v4
Built-in camera-
Interfacemicro USB, RS-232
Storage temperature (T-T)-20 - 70 °C
Operating temperature (T-T)0 - 50 °C
Battery capacity1800 mAh
RFID readerNo
Product colorBlack
Keyboard layoutQWERTY
Keypad number of keys46
Operating system installedWindows Embedded Handheld 6.5
Weight and Dimensions IconWeight and Dimensions
Depth27 mm
Width68 mm
Height144 mm
Weight270 g