Programming
5-278 Magellan
TM
2200VS and 2300HS
Standard 2 of 5 Minimum Label Length
This feature specifies the minimum allowable length of an Standard 2 of 5
label.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET STANDARD 2 OF 5 MINIMUM LABEL
LENGTH
below. Youll need to cover any unused bar codes on this
and the facing page to ensure that the scanner reads only the bar
code you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that rep-
resent the desired minimum label length. The selectable range for
this option is 01 to 50, even numbers only. Pad all single digit num-
bers with a leading zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET STANDARD 2 OF 5 MINIMUM LABEL LENGTH
NOTE
Length in this case includes check and data characters, but does
not include start or stop characters. This feature applies when
Standard 2 of 5 Length Control is set to variable-length decod-
ing.
Minimum label length should be less than or equal to maximum
label length.

Table of Contents

Other manuals for Datalogic Magellan 2200VSΩ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 2200VSΩ and is the answer not in the manual?

Datalogic Magellan 2200VSΩ Specifications

General IconGeneral
BrandDatalogic
ModelMagellan 2200VSΩ
CategoryBarcode Reader
LanguageEnglish

Related product manuals