Standard 2 of 5 Length Control
This feature specifies whether variable-length or fixed-length decoding
will be set for
Standard 2 of 5.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
STANDARD 2 OF 5 LENGTH CONTROL = VARIABLE-LENGTH
STANDARD 2 OF 5 LENGTH CONTROL = FIXED-LENGTH
NOTE
If variable-length control was selected, you must now set the features
Standard 2 of 5 Maximum Label Length and Standard 2 of 5
Minimum Label Length. If fixed-length control was selected, you
must now set Standard 2 of 5 Fixed Length 1 and Standard 2
of 5 Fixed Length 2.