ENVIRONMENTAL FEATURES
Operating Temperature *
0 to 50 °C (32 to 122 °F)
Storage Temperature
-20 to 70 °C (-4 to 158 °F)
Max. Humidity 90% non condensing
Vibration Resistance 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
EN 60068-2-6 2 g @ 70 to 200 Hz; 2 hours on each axis
Bump Resistance 30g; 6 ms;
EN 60068-2-29 5000 shocks on each axis
Shock Resistance 30g; 11 ms;
EN 60068-2-27 3 shocks on each axis
Protection Class EN 60529 IP65
SOFTWARE FEATURES
Readable Code Symbologies
1-D and stacked 2-D POSTAL
• PDF417 Standard and
Micro PDF417
• Code 128 (GS1-128)
• Code 39 (Standard
and Full ASCII)
• Code 32
• MSI
• Standard 2 of 5
• Matrix 2 of 5
• Interleaved 2 of 5
• Codabar
• Code 93
• Pharmacode
• EAN-8/13 - UPC-A/E
(including Addon 2 and
Addon 5)
• GS1 DataBar Family
• Composite Symbologies
• Data Matrix ECC 200
(Standard, GS1 and Direct Marking)
• QR Code
(Standard and Direct Marking)
• Micro QR Code
• MAXICODE
• Aztec Code
• Microglyph
(this symbology requires an activation
procedure – contact your local Datalogic
Automation distributor for details)
• Australia Post
• Royal Mail 4 State
Customer
• Kix Code
• Japan Post
• PLANET
• POSTNET
• POSTNET (+BB)
• Intelligent Mail
• Swedish Post
Operating Mode ONE SHOT, CONTINUOUS, PHASE MODE
Configuration Methods
X-PRESS™ Human Machine Interface
Windows-based SW (VisiSet™) via serial, Ethernet or USB link
Serial Host Mode Programming sequences
Parameter Storage Permanent memory (Flash)
* high ambient temperature applications should use metal mounting bracket for heat dissipation.