EasyManua.ls Logo

Datalogic PowerScan PD953X

Datalogic PowerScan PD953X
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
Product Reference Guide
151
GS1 DATABAR™ OMNIDIRECTIONAL
The following options apply to the GS1 DataBar™ Omnidirectional (formerly
RSS-14) symbology.
GS1 DataBar™ Omnidirectional Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Omnidirectional bar
codes.
DEFAULT
$C4BEN00(CR)
GS1 DataBar™ Omnidirectional = Disable
$C4BEN01(CR)
GS1 DataBar™ Omnidirectional = Enable
GS1 DataBar™ Omnidirectional GS1-128 Emulation
When enabled, GS1 DataBar™ Omnidirectional bar codes will be translated
to the GS1-128 label data format.
DEFAULT
$C4BU800(CR)
GS1 DataBar™ Omnidirectional GS1-128 Emulation = Dis-
able
$C4BU801(CR)
GS1 DataBar™ Omnidirectional GS1-128 Emulation = Enable

Table of Contents

Other manuals for Datalogic PowerScan PD953X

Related product manuals