EasyManua.ls Logo

Datalogic PowerScan PD953X

Datalogic PowerScan PD953X
360 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
36
PowerScan™ PD953X/PBT950X/PM950X
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts
with normal operation of these characters. 8-bit data is not recognized when the option
Data Bits
has been set as 7 Data Bits.
See page 276 for more information on setting this feature.
Select Disable Character Setting
DEFAULT
0x44 = Disable Character is ‘D’
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands con-
flicts with normal operation of these characters. 8-bit
data is not recognized when the
option
Data Bits
has been set as 7 Data Bits.
See page 277 in “References” for more information on setting this feature.
Select Enable Character Setting
DEFAULT
0x45 = Enable Character is ‘E’

Table of Contents

Other manuals for Datalogic PowerScan PD953X

Related product manuals