Symbologies Enter/Exit Programming Mode
Product Reference Guide
217
MSI
The following options apply to the MSI symbology.
MSI Enable/Disable
Enables/Disables ability of reader to decode MSI labels.
MSI Check Character Calculation
Enables/Disables calculation and verification of an optional MSI check charac-
ter.
$CMSEN00
MSI = Disable
$CMSEN01
MSI = Enable
DEFAULT
$CMSCC00
MSI Check Character Calculation = Disable
$CMSCC01
MSI Check Character Calculation = Enable Mod10
$CMSCC02
MSI Check Character Calculation = Enable Mod11/10
$CMSCC03
MSI Check Character Calculation = Enable Mod10/10
DEFAULT

Table of Contents