EasyManua.ls Logo

Datalogic QuickScan I QM2131

Datalogic QuickScan I QM2131
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LED and Beeper Indications
Product Reference Guide
313
Programming Mode
The following indications ONLY occur when the reader is in Programming Mode:
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not
passed its automatic Selftest and has entered FRU (Field Replaceable Unit) iso-
lation mode. If the reader is reset, the sequence will be repeated. The following
table describes the LED flashes/beep codes associated with an error found.
INDICATION DESCRIPTION LED BEEPER
Label Program-
ming Mode
Entry
A valid programming label has
been scanned.
LED blinks continuously
Reader sounds four low fre-
quency beeps.
Label Program-
ming Mode
Rejection of
Label
A label has been rejected. N/A
Reader sounds three times at
lowest frequency & current
volume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where multiple labels
must be scanned to program
one feature, this indication
acknowledges each portion as
it is successfully scanned.
N/A
Reader sounds one short beep
at highest frequency & current
volume.
Label Program-
ming Mode
Acceptance of
Programming
Configuration option(s) have
been successfully pro-
grammed via labels and the
reader has exited Program-
ming Mode.
N/A
Reader sounds one high fre-
quency beep and four low fre-
quency beeps followed by
reset beeps.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned. N/A
Reader sounds two times at
low frequency and current vol-
ume.
NUMBER OF LED
FLASHES/BEEPS
ERROR CORRECTIVE ACTION
1 Configuration
Contact Helpdesk for assis-
tance
2 Interface PCB
4 Reader Module
5 [Reserved]
6 Digital PCB
14 CPLD/Code Mismatch

Table of Contents

Related product manuals