Enter/Exit Programming Mode LED and Beeper Indicators
74 QuickScan™ I QM21X1 / QBT21X1
Good Read: When to Indicate
This feature specifies when the reader will provide indication (beep and/or flash
its green LED) upon successfully reading a bar code. Choices are:
Good Read = Indicate after decode
Good Read = Indicate after transmit
Good Read = Indicate after CTS goes inactive, then active
NOTE
This option, which uses CTS, is only valid for Q21XX models with RS-232
interfaces.
$CBPIN00
Indicate Good Read = After Decode
$CBPIN01
Indicate Good Read = After Transmit
$CBPIN02
Indicate Good Read = After CTS Goes Inactive, Then Active