EasyManua.ls Logo

Datamax E-Class Mark III - Maintenance & Adjustments

Datamax E-Class Mark III
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 – Maintenance and Adjustments 27
4
4
4
M
M
M
a
a
a
i
i
i
n
n
n
t
t
t
e
e
e
n
n
n
a
a
a
n
n
n
c
c
c
e
e
e
&
&
&
A
A
A
d
d
d
j
j
j
u
u
u
s
s
s
t
t
t
m
m
m
e
e
e
n
n
n
t
t
t
s
s
s
4
4
4
.
.
.
1
1
1
I
I
I
n
n
n
t
t
t
r
r
r
o
o
o
d
d
d
u
u
u
c
c
c
t
t
t
i
i
i
o
o
o
n
n
n
This section details the cleaning, adjusting, and troubleshooting tips for the printer. The following table
outlines the recommended maintenance schedule for the various printer parts.
Area Method Interval
Printhead
Turn OFF the printer before cleaning the printhead.
Use solvent* applied with a cotton swab to clean
the printhead from end to end.
After every roll of media.
Platen Roller
Turn OFF the printer. Rotate the platen roller and
clean it thoroughly with solvent* applied with a
cotton swab.
After every roll of media.
Peel-Off Roller
Rotate the peel-off roller and clean it thoroughly
with solvent* applied with a cotton swab.
After every roll of media.
Media Path Solvent* After every roll of media.
Peel/Tear Bar Solvent* As needed
Media Sensor Blown air or brush Monthly
Exterior Mild detergent or desktop cleaner. As needed
Interior Brush or vacuum cleaner As needed.
* A solvent containing isopropyl alcohol is recommended for use.
Isopropyl alcohol is a flammable solvent; always take the proper precautions when in use.

Other manuals for Datamax E-Class Mark III