EasyManuals Logo

Datamax Mark II User Manual

Datamax Mark II
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Chapter 3 – Printer Operation 21
3.7.3 Standard Calibration
The Standard Calibration can be performed using the DMXConfig Utility (see Section 3.5), or via the front
panel buttons (see Appendix B).
Once you have installed the DMXConfig utility and the printer is properly loaded with media, proceed with
calibration as follows:
1. Connect the host to the printer with a serial
or parallel cable.
2. Turn ON the printer.
3. Launch the DMXConfig utility.
4. Query the printer by using the Query Printer
toolbar button (top-left). This will connect to
the printer and get the current printer
settings.
5. Select the Sensor Calibration Tab and then
click the Media Calibration Wizard button.
When prompted click OK to start the
calibration wizard.
6. The Calibration Wizard will now prompt you to
Load Stock. Ensure that media is properly
loaded in the printer then close the printhead
and click OK.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax Mark II and is the answer not in the manual?

Datamax Mark II Specifications

General IconGeneral
Print MethodThermal Transfer/Direct Thermal
Resolution203 dpi
Max Print Speed6 ips (152 mm/s)
ConnectivityUSB, Serial, Parallel, Ethernet
Media SensorReflective/Transmissive
Processor32 bit RISC processor
Media TypesLabels, Tags, Tickets
Media Thickness0.002 to 0.010 inches
Power Source100-240V AC, 47-63 Hz
Ribbon Width1.0 to 4.25 inches

Related product manuals