W-Class 57
Standard Calibration (continued)
Step Operator Action Displayed Message Comment
7
Proceed according to
your media type:
Die-cut stock: strip the
media from the backing
and then reinsert it into
the sensor; adjust the
Sensor Eye Mark over
the center of the backing.
Notched stock: adjust
the Sensor Eye Mark
over the center of the
notch.
Reflective stock: Adjust
the Sensor Eye Mark
over the center of the
facedown black mark.
Continuous stock: go to
Step 8.
Press any key to
continue.
SCAN BACKING
PRESS ANY KEY <yyy>
Or, for reflective media:
SCAN MARK
PRESS ANY KEY <yyy>
This sets the
parameter for the
‘gap’ or ‘mark
value.
Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.
ã Note: Never
position the
sensor over a
perforation when
recording a
sensor reading.
ã Note: Do not move the position of the Media Sensor after it has been
adjusted.
8
Position the label (and
backing, if any) under
the Sensor Eye Mark.
ã Note: If using
preprinted media,
ensure the label area
under the sensor is
free of preprinted text,
graphics or borders.
Press any key to
continue.
SCAN PAPER
PRESS ANY KEY <yyy>
This sets the
parameter for the
‘paper’ value.
Where ‘yyy’ is a
numerical value
representing the
current sensor
reading.