W-Class 57
Standard Calibration (continued)
 Step  Operator Action  Displayed Message  Comment
 
 7
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Proceed according to
your media type:
 
 Die-cut stock: strip the
media from the backing
and then reinsert it into
the sensor; adjust the
Sensor Eye Mark over
the center of the backing.
 
 Notched stock: adjust
the Sensor Eye Mark
over the center of the
notch.
 
 Reflective stock: Adjust
the Sensor Eye Mark
over the center of the
facedown black mark.
 
 Continuous stock: go to
Step 8.
 
 Press any key to
continue.
 
 
 
SCAN BACKING
 
PRESS ANY KEY   <yyy>
 
 Or, for reflective media:
 
 
SCAN MARK
 
PRESS ANY KEY   <yyy>
 
 This sets the
parameter for the
‘gap’ or ‘mark’
value.
 
 Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.
 
 
ã Note: Never
position the
sensor over a
perforation when
recording a
sensor reading.
 
 
 
 
 
 
 
ã Note: Do not move the position of the Media Sensor after it has been
adjusted.
 
 
 8
 
 Position the label (and
backing, if any) under
the Sensor Eye Mark.
 
 
ã Note: If using
preprinted media,
ensure the label area
under the sensor is
free of preprinted text,
graphics or borders.
 
 Press any key to
continue.
 
 
 
SCAN PAPER
 
PRESS ANY KEY  <yyy>
 
 
 
 This sets the
parameter for the
‘paper’ value.
 
 Where ‘yyy’ is a
numerical value
representing the
current sensor
reading.