GW/ALARM> dtrunk alarm ©
---------------------------------------------------------------------------
ALARM DESCRIPTION
---------------------------------------------------------------------------
FOOS : Frame Out Of Sync
CSOOS : CRC multiframe Out Of Sync
MFOOS : Multiframe Out Of Sync
LOS : Loss Of Signal
AIS : Alarm Indication Signal
AIS16 : AIS on channel 16
RAI : Remote Alarm Indication
MFALM : Remote signalling Multiframe Alarm
SLIP : Accuracy of Master Clock
---------------------------------------------------------------------------
---------------------------------------------------------------------------
SLOT/TRUNK : CURRENT-STATE
---------------------------------------------------------------------------
0/0 : NO-ALARM
---------------------------------------------------------------------------
FOOS CSOOS MFOOS LOS AIS AIS16 RAI MFALM SLIP
---------------------------------------------------------------------------
0 0 0 0 0 0 0 0 1
---------------------------------------------------------------------------
---------------------------------------------------------------------------
SLOT/TRUNK : CURRENT-STATE
---------------------------------------------------------------------------
0/1 : NO-ALARM
---------------------------------------------------------------------------
FOOS CSOOS MFOOS LOS AIS AIS16 RAI MFALM SLIP
---------------------------------------------------------------------------
0 0 0 0 0 0 0 0 1
---------------------------------------------------------------------------
GW/ALARM>
* If you see constantly increasing slips in alarm, you have to check clock configuration
(Master/Slave) in PBX. Otherwise, make sure that your connecting cable is working properly. As you
can see above, it is normal to see one slip in a fresh boot.
* You have to check frame mode in digital trunk configuration when CSOOS alarms are increasing
without a slip. For instance, you can see CSOOS alarms increasing without a slip if GW uses CRC4
and PBX uses NOCRC4.