WARNING:
Do not remove the pressure regulator
from the cooktop.
To convert the regulator from Natural Gas to LP
gas or LP to Natural, remove the cap screw, us-
ing an adjustable wrench, and reverse the plas-
tic plunger (make sure the plunger is firmly
swapped and seated in the cap screw).
WARNING:
Check for leaks before attempting to light
the burners.
Do not use a flame to check for gas leaks.
Check to be sure all controls are in the
OFF position.
Turn on the gas supply at the shutoff
valve.
Use a leak detector at all connections. If
a leak is detected, tighten the connec-
tion and test again.
Replace the cooktop, reconnect the wiring and
reassemble the burners as shown on page 16.
Check for proper ignition:
Connect Electrical.
Push in one control knob and turn 90°
to HI position.
The igniter will spark, and the burner will
light. The igniter will cease sparking
when the burner is lit (all of the burners
will spark).
This test may require some time while
air is flushed out of the gas line.
Turn the knob to OFF.
Repeat the procedure for each burner.
3. CONVERT THE PRESSURE
REGULATOR
4. CHECK FOR LEAKS
5. ASSEMBLE BURNERS AND CHECK
IGNITION