STEP 3 SYSTEM INFORMATION
From this page it is possible to view the modules that make up the system. It is also possible to monitor the voltage and current
status of each individual module and any warnings or alarms.
STEP 4 MODULE INFORMATION
From this page it is possible to view the individual cells of each module by selecting the desired module at the bottom
of the screen.
STEP 5 HV BOX FIRMWARE UPGRADE
By selecting the SEARCH NEW FIRMWARE, it is possible to search for the new HV BOX Firmware available (visit
www.DD5300-BMS.com to find the latest version). After selecting the file, press LOAD FIRMWARE to launch the
Firmware Upgrade.
After confirming the File and clicking on the LOAD FIRMWARE button, the update procedure will begin and the HV BOX will be
updated to the latest version.
The internal contactor may open and close several times after the update procedure is completed.