V0208, 2.16
Function
When set to 1, the retract function is enabled. Several parameters (37-40) will become
available and can be programmed.
Parameter 37
Auto retract enable
Range : 0 - 1
Unit : -
Default : 0
Remark
Only if ‘Retract programmable’ (36) is set to 1.
Function
When set to 1, retract is automatically started on the high-to-low transition of the input ST,
which is the moment to start cutting.
When set to 0, the backgauge is only retracted when the R input becomes high.
Parameter 38
Minimum retract
Range : 0.0 – 9999.9
Unit : mm
Default : 0.0
Remark
Only if ‘Retract programmable’ (36) is set to 1.
Function
Minimum retract value.
Parameter 39
Retract hold
Range : 0.0 - 999.9
Unit : seconds
Default : 0
Remark
Only if ‘Retract programmable’ (36) is set to 1.
Function
Holdtime, to keep the X-axis at the retract position.
Parameter 40
Default retract