V0208, 2.10
2.2. Backgauge control parameters
Parameter 19
Control type
Range : 0 - 3
Unit : -
Default : 3
Function
The type of motor system that is to be controlled.
0 = No control
1 = 1-speed AC or DC drive
2 = 2-speed AC or DC drive
3 = Servo motor drive
According to this setting, parameters for Servo or for AC will appear for programming. See
also chapter 1 about drive types.
Parameter 20
X-speed programmable
Range : 0 - 1
Unit : -
Default : 0
Remark
Only if ‘Control Type’ (19) is set to 3.
Function
This parameter defines whether or not the speed of the axis can be programmed in user
mode. If enabled, then in programming mode and manual mode the operator can program the
axis speed in a percentage of the maximum speed.
0 = no speed parameter for operator (default setting)
1 = speed programmable
Parameter 21
Minimum value
Range : 0.00 - 9999.99
Unit : mm
Default : 1.00
Function
Minimum backgauge position. The axis will never be controlled to a lower position than
programmed here.
Parameter 22
Maximum value
Range : 0.00 - 9999.99