Delem
V0208, 2.11
Unit : mm
Default : 1000.00
Function
Maximum backgauge position. The axis will never be controlled to a higher position than
programmed here.
Parameter 23
Manual speed high
Range : 1 - 100
Unit : %
Default : 50
Function
Speed of the axis, when it is moved in manual mode with the ‘manual move’ function. This is
the travel speed when the arrow key is pressed continuously. This parameter should be
programmed as a percentage of the maximum speed.
Parameter 24
Decimal point position
Range : 0 - 2
Unit : -
Default : 1
Function
0 = 1 mm / 0.1 inch resolution
1 = 0.1 mm / 0.01 inch resolution
2 = 0.01 mm / 0.001 inch resolution
Parameter 25
X/Gap correction enable
Range : 0 - 1
Unit : -
Default : 0
Function
When this parameter is set to 1, the position value of the X-axis is adjusted according to
adjustment of the Gap.
0 = no correction
1 = correction with Gap distance