V0208, 2.12
2.g
Parameter 26
Enable display correction
Range : 0 - 1
Unit : -
Default : 0
Function
When the axis reaches the programmed position, the display can show the real measured
position or it can show the programmed position. This can be programmed with this
parameter.
If this parameter is programmed to 1, the display shows the programmed position when the
axis position is within the ‘In Position’ tolerance.
0 = real actual values are shown
1 = programmed value is shown when axis in position
In both cases, the value is highlighted when the axis is within the IP tolerance.
Parameter 27
X-correction enable
Range : 0 - 1
Unit : -
Default : 0
Function
To provide an X-axis correction parameter for the operator. When switched on, the operator
can program a global X-axis correction that is valid for each program step.
0 = no correction parameter available
1 = X-axis correction available
Parameter 28
Pre scaling
Range : 1.000 - 9999.999