V0208, 2.36
Cut: program a known force value (in kiloNewtons) for a cut.
DA-value: program the required output voltage for this force. The output voltage must be
programmed in the range 0-4095, it will be converted to an output voltage in the range 0-10V.
Parameter 96
Main force ramp
Range : 0 - 9999
Unit : msec
Default : 200
Function
This parameter describes the ramp for the main force (increase/decrease). It is programmed
as the time in which the force output increases from minimum to maximum voltage.
Parameter 97
Cutting force delay
Range : 0 - 999
Unit : msec
Default : 0
Function
After the ‘ST’ input goes low, the control will start force control. This parameter can be used to
program a delay before force control is started.
Parameter 98
Blade-up hold time
Range : 0 - 999
Unit : msec
Default : 0
Function