NOTE: Ensure that you correctly install the PSU. When you install the PSU correctly, the power connector is on the left side of
the PSU.
NOTE: If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, install the power
supply in the rst slot, PSU1. Install a blank plate in the second slot, PSU2.
1 Remove the PSU slot cover from the S5200F-ON Series switch using a small #1 Phillips screwdriver.
2 Remove the PSU from the electro-static bag.
3 Insert the PSU into the switch PSU slot—insert the exposed PSU connector rst.
The PSU slot is keyed so that you can only fully insert the PSU in one orientation. When you install the PSU correctly, it snaps into
place and is ushed with the back of the switch.
4 Plug in the appropriate AC 3-prongs cable from the switch PSU to the external power source.
5 Repeat steps 1 through 4 if you have a redundant PSU using the second PSU slot on the S5200F-ON Series switch.
Figure 22. S5232F-ON or S5248F-ON switch PSUs
1
PSU1 is on the right side of the switch. PSU2 is on the left
side of the switch.
38 Power supplies