Alignment and Troubleshooting
4-50
Service Manual
5) Multi-Feeding
Description : Multiple sheets of paper are fed at once.
1. Solenoid malfunction
(the solenoid does not work properly):
Perform DCU Diagnostic
Code 06.
2. Cassette holder pad is
contaminated with foreign
matter.(oil...)
Replace the solenoid if necessary.
Clean the pad friction with soft
clothe dampened with IPA
(Isopropyl Alcohol).