EasyManua.ls Logo

Dell EMC PowerEdge R550 - Removing the Right Control Panel

Dell EMC PowerEdge R550
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Next steps
1. Install the cooling fan cage assembly.
2. Install the drive backplane cover.
3. Install the air shroud.
4. Follow the procedure listed in the After working inside your system.
Removing the right control panel
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Remove the drive backplane cover.
5. Remove the cooling fan cage assembly.
Steps
1. Disconnect the right control panel cable and the VGA cable from the connectors on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Remove the cable from cable clip.
3. Using the Phillips #1 screwdriver, remove the screws that secures the right control panel and cable cover to the system.
4. Holding the right control panel assembly, remove the control panel along with the cable from the system.
NOTE: The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Installing and removing system components 111