Dell EMC PowerEdge R550 - Intrusion Switch Module; Removing the Intrusion Switch Module

Dell EMC PowerEdge R550
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 31. Installing the side wall bracket
Next steps
1. Install the air shroud.
2. Install the cooling fan cage assembly .
3. Follow the procedure listed in the After working inside your system.
Intrusion switch module
This is a service technician replaceable part only.
Removing the intrusion switch module
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud.
4. Disconnect the system power cable from the system board.
Steps
1. Disconnect the intrusion switch cable from the connector on the system board.
NOTE: Observe the routing of the cable as you remove it from the system.
2. Using the Phillips #1 screwdriver, remove the screw securing the intrusion switch module.
Installing and removing system components
43