k. Cooling fan assembly
l. Cooling shroud
m. Power supply unit(s)
3. Reconnect all cables to the system board.
NOTE: Ensure that the cables inside the system are routed along the chassis wall and secured using the cable securing
bracket.
4. Follow the procedure listed in the After working inside your system section.
5. Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller
User's Guide, at Dell.com/esmmanuals.
6. Ensure that you:
a. Use the Easy Restore feature to restore the Service Tag. For more information, see the Easy restore section.
b. If the Service Tag is not backed up in the backup flash device, enter the Service Tag manually. For more information, see
the Entering the Service Tag section.
c. Update the BIOS and iDRAC versions.
d. Re-enable the Trusted Platform Module (TPM). For more information, see the Re-enabling the Trusted Platform Module
(TPM) section.
Related tasks
Installing the cable retention bracket on page 111
Installing the PCIe card holder on page 108
Installing the hard drive tray on page 78
Installing the integrated storage controller card on page 114
Replacing the optional internal USB memory key on page 140
Installing the optional internal dual SD module on page 136
Installing expansion card risers on page 130
Installing a heat sink on page 106
Installing a processor on page 104
Installing memory modules on page 97
Installing the network daughter card on page 138
Installing the cooling fan assembly on page 89
Installing the cooling shroud on page 76
Installing an AC power supply unit on page 145
Installing a DC power supply unit on page 150
Entering the system Service Tag by using System Setup
If Easy Restore fails to restore the Service Tag, use System Setup to enter the Service Tag.
Steps
1. Turn on the system.
2. Press F2 to enter System Setup.
3. Click Service Tag Settings.
4. Enter the Service Tag.
NOTE: You can enter the Service Tag only when the Service Tag field is empty. Ensure that you enter the correct
Service Tag. After the Service Tag is entered, it cannot be updated or changed.
5. Click OK.
6. Import your new or existing iDRAC Enterprise license.
For more information, see the Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals .
156 Installing and removing system components