EasyManua.ls Logo

Dell EMC PowerEdge R740 - Particulate and Gaseous Contamination Specifications

Dell EMC PowerEdge R740
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Thermal restrictions
Following table lists the conguration required for ecient cooling.
Table 30. Thermal restrictions conguration
Conguration Number of
processors
Heatsink Processor/DIMM
blank
DIMM
blanks
Type of air
shroud
Fan
PowerEdge
R740
1 One 1U standard heat sink for
CPU ≤ 125 W
Required Not
required
Standard Four standard
fans and one
blank to cover
two fan slots
One 2U standard heat sink for
CPU > 125 W
PowerEdge
R740
2 Two 1U standard heat sink for
CPU ≤ 125 W
Not required Not
required
Standard Six standard fans
Two 2U standard heat sink for
CPU > 125 W
PowerEdge
R740 with GPU
2 Two 1U high performance
heat sink
Not required Not
required
GPU air shroud Six high
performance
fans
Ambient temperature limitations
The following table lists congurations that require ambient temperature less than 35°C.
NOTE
: The ambient temperature limit must be adhered to ensure proper cooling and to avoid excess CPU throttling, which may
impact system performance.
Table 31. Conguration based ambient temperature restrictions
System Front backplane CPU Thermal
Design Power
(TDP)
CPU heat sink Fan type GPU Ambient
restriction
PowerEdge
R740
8 x 3.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
8 x 2.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
16 x 2.5 inch SAS/
SATA
150 W/8 core, 165
W/12 core, 200
W, 205 W
1U high
performance
High performance
fan
≥1 double-width/
single-width
30°C
Particulate and gaseous contamination specications
The following table denes the limitations that help avoid any equipment damage or failure from particulate and gaseous contamination. If
the levels of particulate or gaseous pollution exceed the specied limitations and result in equipment damage or failure, you may need to
rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer.