76 | Alarms
www.dell.com | support.dell.com
Power Supplies and Alarms
If a Power Supply fails while the E1200i is operating, the software generates a major alarm and an SNMP
trap, lights the major LED, and activates the audible alarm.
When a Power Supply fails, the software also records one alarm event for line cards, RPM, and SFM,
though each contains its own power source. The system generates one alarm event and SNMP trap
summarizing the Power Supply failure and the components affected.
Fan tray More than one fan within the module
fails or hardware failure in the
module
major (red) major amber yes
One fan within the module fails minor (amber) minor amber no
AC Power
Supplies
Hardware failure in a non-redundant
power configuration (3 power
supplies)
major (red) major red or unlit yes
Hardware failure in a redundant
power configuration (4 power
supplies)
minor (amber) minor red or unlit no
Line Card Hardware failure major (red) major amber no
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green yes
Individual interface fails minor (amber) reported amber
b
no
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
RPM fails but CP is ok major (red) major amber yes
SFMs (Redundant Configuration with 10 SFMs)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
Any card fails minor (amber) minor amber no
Any card removed minor (amber) minor unlit no
8 SFMs (Non-Redundant Configuration)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
Any card fails major (red) major amber yes
Any card removed major (red) major unlit yes
a. Event appears only in the show alarms command output.
b. The interface’s Link LED is unlit.
Table C-1. Alarm Events and Reporting
Module Alarm Event Alarm LED Reported in
event log
Status LED on
Module
Audible
Alarm?