174 Configuring System Information
www.dell.com | support.dell.com
Displaying the Trap Managers Table:
The Trap Managers Table contains fields for configuring trap types.
1 Open the Traps page.
2 Click Show All. The Traps Manager Table page opens.
Trap Managers Table Page
Deleting a Trap Manager Table entry:
1 Open the SNMP Trap Settings page.
2 Click Show All. The Traps Manager Table page opens.
3 Select a Trap Managers Table entry.
4 Check the Remove check box.
5 Click Apply Changes. The trap manager is deleted, and the device is updated.
Configuring Traps Using CLI Commands
The following table summarizes the equivalent CLI commands for viewing fields displayed
in the SNMP Trap Settings page.
CLI Command Description
snmp-server enable traps Enables the switch to send SNMP traps or
SNMP notifications.
snmp-server trap
authentication
Enables the switch to send SNMP traps
when authentication failed.
snmp-server host host-addr
community-string [1 | 2]
Determines the trap type sent to the
selected recipient.

Table of Contents