Ingress filtering is always enabled on Trunk-mode ports. Incoming frames 
will undergo ingress filtering, and if correctly tagged, (tagged with a VID of 
one of the VLANs to which the port currently belongs) are admitted. 
The default PVID is 1 (the default VLAN). If another VID is configured as 
the port’s PVID, and the corresponding VLAN is deleted from the port or 
from the system, the port’s PVID reverts to 1, meaning that the port is 
made a member of the default VLAN.
Setting a trunk-port’s PVID to 4095 limits traffic to tagged frames. 
Incoming untagged frames are silently discarded, and no frames are sent 
untagged.
Trunk-mode ports are intended for switch-to-switch links, where traffic is 
usually tagged.
• General Ports
Ports set to General mode may be members of multiple VLANs. Each of 
these VLANs may be configured to be tagged or untagged. This setting 
applies to transmitted frames. Incoming untagged frames are classified 
into the VLAN whose VID is the currently configured PVID. 
Ingress filtering may be disabled on General ports. Ingress filtering is 
enabled by default. 
• Promiscuous Ports
A promiscuous port can communicate with all ports of the same Private 
VLAN (PVLAN), including the isolated ports of the same PVLAN. 
•Isolated
An isolated port has complete Layer 2 isolation from the other ports within 
the same PVLAN, but not from the promiscuous ports. Isolated ports can 
communicate with promiscuous ports.
In the factory default configuration, all ports are designated as Access ports, 
and are associated with the default VLAN.