EasyManua.ls Logo

Dell PowerEdge C6400 - Max Continuous Operating Temperature (Non-Fabric Single Processor)

Dell PowerEdge C6400
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TDP
(W)
Process
or
model
number
Max
DIMM
count
per CPU
12x 3.5”
HDDs
enclosur
e
8x 3.5”
HDDs
enclosur
e
4x 3.5”
HDDs
enclosur
e
24x 2.5”
HDDs
enclosur
e
20x 2.5”
HDDs
enclosur
e
16x 2.5”
HDDs
enclosur
e
12x 2.5”
HDDs
enclosur
e
8x 2.5”
HDDs
enclosur
e
4x 2.5”
HDDs
enclosur
e
No back
plane
enclosur
e
160W
8160F
CPU1: 6
| CPU2:
8
Not applicable
25°C/
77°F
25°C/
77°F
25°C/
77°F
30°C/
86°F
30°C/
86°F
6148F
CPU1: 6
| CPU2:
8
25°C/
77°F
25°C/
77°F
25°C/
77°F
30°C/
86°F
30°C/
86°F
6142F
CPU1: 6
| CPU2:
8
25°C/
77°F
25°C/
77°F
25°C/
77°F
30°C/
86°F
30°C/
86°F
135W
6138F
CPU1: 8
| CPU2:
8
Not applicable
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
6130F
CPU1: 8
| CPU2:
8
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
6126F
CPU1: 8
| CPU2:
8
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
113W
5117F
CPU1: 8
| CPU2:
8
Not applicable
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
Table 21. Maximum continuous operating temperature for non-fabric single processor conguration
TDP
(W)
Process
or
model
number
Max
DIMM
count
per CPU
12x 3.5”
HDDs
enclosur
e
8x 3.5”
HDDs
enclosur
e
4x 3.5”
HDDs
enclosur
e
24x 2.5”
HDDs
enclosur
e
20x 2.5”
HDDs
enclosur
e
16x 2.5”
HDDs
enclosur
e
12x 2.5”
HDDs
enclosur
e
8x 2.5”
HDDs
enclosur
e
4x 2.5”
HDDs
enclosur
e
No back
plane
enclosur
e
205W
8180
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8180M
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8168
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
200W
6154
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
165W
6150
CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
6146
CPU1: 6
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
8176
CPU1: 8
30°C/
86°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
35°C/
95°F
Dell PowerEdge C6400 Installation and Service Manual
Technical specications
27

Table of Contents

Related product manuals