EasyManuals Logo

Dell PowerSwitch S4048-ON User Manual

Dell PowerSwitch S4048-ON
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Table 7. Environmental parameters(continued)
Parameter Specifications
Shock Meets Bellcore Zone 4 earthquake requirements (MIL-
STD-810)
Table 8. AC power requirements
Parameter Specifications
Power supply 100240 VAC 50/60 Hz
Maximum current draw per system
5.8 A @ 398.02 watts/100vac
2.9 A @ 398.02 watts/200vac
Maximum power consumption 460 Watts
Typical power consumption 338 Watts
Reliability MTBF 355.178 hours
IEEE standards
The S4048ON complies with the following IEEE standards:
802.3ab Gigabit Ethernet (1000BASE-T)
802.3ae 10-Gigabit Ethernet (10GBASE-X)
802.3ba 40-Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
802.3u Fast Ethernet (100BASE-TX)
802.3z Gigabit Ethernet (1000BASE-X)
Agency compliance
The S4048ON is designed to comply with the following safety and agency requirements.
Network Equipment Building Systems Compliance
Use shielded cables for ports from 0 to 48. Ground the shields at both ends.
Use only reverse airflow configurations in a NEBS-compliant installation.
Fit the power supplies and fan modules with filter kits. Replace the fan filters regularly.
Use this equipment with an external, second-level 6 kV lightning surge protective device (SPD) at the AC input of the
building.
Use an SPD with the AC power connections to protect the AC power supplies from damage from excessive power line
surges.
In order to comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC Power Ports, use an SPD at the
AC input of the router.
WARNING:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel
ground strap when handling the S4048-ON and its components.
USA Federal Communications Commission Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designated to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and
used in accordance to the instructions, it may cause harmful interference to radio communications. Operation of this equipment
Specifications
37

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerSwitch S4048-ON and is the answer not in the manual?

Dell PowerSwitch S4048-ON Specifications

General IconGeneral
Switching Capacity1.44 Tbps
AirflowFront-to-back or back-to-front
ManageableYes
Total Number of Network Ports54
Uplink Port6 x 40GbE QSFP+
Number of 40 Gigabit Ethernet Ports6
Number of 10 Gigabit Ethernet Ports48
Media Type SupportedOptical Fiber, Twisted Pair
Ethernet Technology10 Gigabit Ethernet, 40 Gigabit Ethernet
Layer SupportedLayer 2, Layer 3
Form FactorRack-mountable
Operating Temperature32 °F to 104 °F (0 °C to 40 °C)
Power SupplyDual, hot-swappable
Dimensions1.7 inches
Product TypeLayer 3 Switch
Port/Expansion Slot Details48 x 10GbE SFP+, 6 x 40GbE QSFP+
Network Technology40GBase-X
Input Voltage100-240 VAC
Height1.7 inches
Width17.3 inches
Ports48 x 10GbE, 6 x 40GbE
Weight24.5 lbs