LED behavior
The following S4048ON switch LED behavior is seen during open networking installation environment (ONIE) operations:
Figure 5. S4048ON LEDs
1. Master LED
2. System LED
3. Power LED
4. Fan LED
5. Locator LED
6. SFP+ link or activity LEDs
7. Stack LED
8. USB port LED
9. QSFP+ link or activity LEDs
Table 1. S4048ON LED behavior
LED Description
System Status or Health LED
Solid greenNormal operation
Flashing greenBooting
Solid amberCritical system error
Flashing amberNoncritical system error, fan failure, or
power supply failure
Power LED
OffNo power
Solid GreenNormal
Solid amberPOST is in process.
Flashing amberPower supply failed
MASTER LED
OffSwitch is in Stacking Slave mode.
Solid greenSystem is in Stacking Master or Standalone
mode.
FAN LED
Solid greenfan that is powered and running at the
expected RPM.
Solid amberfan failed including incompatible airflow
direction when you insert the PSU or fan trays with
differing airflows.
PSU LED
Solid greenNormal operation
Solid amberPower supply critical event causing a
shutdown
The S4048ON switch 9